Hycrete Products
Technical Details
Find The Best Details For Your Project – As a professional courtesy, Hycrete, Inc. offers technical services free of charge. The User maintains all responsibility for verifying the applicability and suitability of the technical service or information provided. Conditions vary, and there may be a better detail for your project. Contact us to check whether Hycrete products and services are suitable for your application, and to get advice on value engineering your project.
CAD Details – Concrete fits into whatever shape you want, so these details probably don’t exactly match your project. Contact us to have CAD or PDF details prepared for your project – no additional charge.
Belt and Suspenders / Green Roofs – Please use the relevant detail and add your preferred membrane details. Contact us if you would like us to draw up the Hycrete details for your project.
BELOW GRADE AND RETAINING WALLS | |||||||
Detail # | Detail Title | Location | Detail Type | Pour Type | Application | CAD | |
---|---|---|---|---|---|---|---|
Wall-Slab Joint | |||||||
7001001 | Wall-Slab Joint Detail CIP Wall – Footing Poured Integrally With Slab | Below grade | Wall-Slab Joint | Cast-in-place wall | Below grade parking, mechanical rooms, unoccupied space | N/A | |
7002001 | Wall-Slab Joint Detail CIP Wall – Footing Poured Integrally With Slab | Below grade | Wall-Slab Joint | Cast-in-place wall | Below grade parking, mechanical rooms, unoccupied space | N/A | |
7003001 | Wall-Slab Joint Detail CIP Wall – Slab Over 12 in Thick, Value Engineered | Below grade | Wall-Slab Joint | Cast-in-place wall | Below grade parking, mechanical rooms, unoccupied space | N/A | |
7004001 | Wall-Slab Joint Detail Shotcrete Wall | Below grade | Wall Slab Joint | Shotcrete wall | Below grade parking, mechanical rooms, unoccupied space | N/A | |
7005001 | Wall-Slab Joint Detail Shotcrete Wall – Wall over 12 in Thick, Value Engineered | Below grade | Wall-Slab Joint | Shotcrete wall | Below grade parking, mechanical rooms, unoccupied space | N/A | |
Wall-Elevated Slab Joint | |||||||
7011001 | Wall-Elevated Slab Joint Detail CIP Wall | Below grade | Wall-Elevated Slab Joint | Cast-in-place wall | Below grade parking, mechanical rooms, unoccupied space | N/A | |
7012001 | Wall-Elevated Slab Joint Detail Shotcrete Wall | Below grade | Wall-Elevated Slab Joint | Shotcrete wall | Below grade parking, mechanical rooms, unoccupied space | N/A | |
Pilaster Wall Joint | |||||||
7021001 | Pilaster-Wall Joint Detail CIP Wall | Below grade | Pilaster | Cast-in-place wall | Below grade parking, mechanical rooms, unoccupied space | N/A | |
7022001 | Pilaster-Wall Joint Detail Shotcrete Wall | Below grade | Pilaster | Shotcrete wall | Below grade parking, mechanical rooms, unoccupied space | N/A | |
Column or Shear Wall-Slab Joint | |||||||
7031001 | Column or Shear Wall-Slab Detail | Below grade | Column or Shear Wall-Slab Joint | Cast-in-place wall | Below grade parking, mechanical rooms, unoccupied space | N/A | |
Elevator Pit or Sump Pit | |||||||
7041001 | Elevator Pit or Sump Pit Detail | Below grade | Elevator Pit or Sump Pit | Cast-in-place wall | Elevator pit, sump pit | N/A | |
Groutable Hose Waterstop System | |||||||
7051001 | Groutable Hose Waterstop Junction Box Positioning | Below grade | Wall-Slab Joint; Wall-Elevated Slab Joint | Shotcrete wall | Below grade parking, mechanical rooms, unoccupied space | N/A | |
7052001 | Groutable Hose Waterstop Junction Box Detail | Below grade | Wall-Slab Joint; Wall-Elevated Slab Joint | Shotcrete wall | Below grade parking, mechanical rooms, unoccupied space | N/A | |
De-Watering Sump Series | |||||||
7061001 | De-Watering Sump Pump Detail | Below grade | Slab | Cast-in-place slab | Below grade parking, mechanical rooms, unoccupied space, elevator pit, sump pit, retention tank | N/A | |
Below-Grade Penetrations | |||||||
7071001 | Tie-Back Detail | Below grade or Retaining wall | Wall | Cast-in-place wall | Below grade parking, mechanical rooms, unoccupied space, elevator pit, sump pit, retaining wall, retention tank | N/A | |
7072001 | Wall Pipe Penetration Details | Below grade or Above grade | Wall | CIP or Shotcrete wall | Below grade parking, mechanical rooms, unoccupied space, elevator pit, sump pit, retaining wall, retention tank | N/A | |
7075001 | Tapered Tie Wall Penetration Detail | Below grade or Retaining wall | Wall | Cast-in-place wall | Below grade parking, mechanical rooms, unoccupied space, elevator pit, sump pit, retaining wall, retention tank | N/A | |
7076001 | Snap Tie Wall Penetration Detail | Below grade or Retaining wall | Wall | Cast-in-place wall | Below grade parking, mechanical rooms, unoccupied space, elevator pit, sump pit, retaining wall, retention tank | N/A | |
7077001 | Slab Pipe Penetration Details | Below grade or Above grade | Slab | Cast-in-place slab | Below grade parking, mechanical rooms, unoccupied space, elevator pit, sump pit, retention tank | N/A | |
7078001 | Link Seal Slab Penetration Detail | Below grade or Above grade | Slab | Cast-in-place wall or slab | Below grade parking, mechanical rooms, unoccupied space, elevator pit, sump pit, retention tank | N/A | |
7079001 | Floor Drain Slab Penetration Detail | Below grade or Above grade | Slab | Cast-in-place slab | Below grade parking, mechanical rooms, unoccupied space, elevator pit, sump pit, retention tank | N/A | |
Re-Entrant Corners | |||||||
7101001 | Re-Entrant Corners Detail | All locations | Slab | CIP or shotcrete slab or wall | All applications | N/A | |
ELEVATED SLABS – PLAZA/PODIUM DECK; GREEN ROOF; ROOF OVER UNOCCUPIED SPACE | |||||||
Joints | |||||||
7201001 | Plaza or Podium Deck/External Wall Joint Detail | Elevated slab: Podium/plaza deck; Green roof; Roof over unoccupied space | Slab/External Wall | Cast-in-place slab | Elevated slab over unoccupied space | N/A | |
7201002 | Plaza or Podium Deck/Parapet Wall Joint Detail | Elevated slab: Podium/plaza deck; Green roof; Roof over unoccupied space | Slab/Parapet Wall | Cast-in-place slab | Elevated slab over unoccupied space | N/A | |
7201003 | Post-Tensioned Deck Joints and Closure | Elevated slab: Podium/plaza deck; Green roof; Roof over unoccupied space | Slab | Cast-in-place slab | Elevated slab over unoccupied space | N/A | |
Above-Grade Penetrations | |||||||
7072001 | Wall Pipe Penetration Details | Below grade or Above grade | Wall | CIP or shotcrete wall | Below grade parking, mechanical rooms, unoccupied space, elevator pit, sump pit, retaining wall, retention tank | N/A | |
7077001 | Slab Pipe Penetration Details | Below grade or Above grade | Slab | Cast-in-place slab | Below grade parking, mechanical rooms, unoccupied space, elevator pit, sump pit, retaining wall, retention tank | N/A | |
7078001 | Link Seal Slab Penetration Details | Below grade or Above grade | Slab | Cast-in-place wall or slab | Below grade parking, mechanical rooms, unoccupied space, elevator pit, sump pit, retaining wall, retention tank | N/A | |
7079001 | Floor Drain Slab Penetration Details | Below grade or Above grade | Slab | Cast-in-place slab | Below grade parking, mechanical rooms, unoccupied space, elevator pit, sump pit, retaining wall, retention tank | N/A | |
Water Tank | |||||||
7301001 | Water Tank Above Grade Detail | Water Tank | Water Tank | Cast-in-place slabs and walls | Water tank above grade | N/A | |
Integral Admixture as Backup Waterproofing System (Secondary) | |||||||
7201004 | Belt and Suspender application | Below grade or Above grade | Wall Joint/Deck Slab | CIP or shotcrete | Below grade wall Elevated Deck Slab | N/A |